OP712 USB Optical Power Meter

Advancing the World of Fiber Optics™

OptoTest_OP712
Click image to enlarge

The OP712 is a standalone USB powered and operated power meter. It can be integrated into the test and measurement process with any OptoTest Applications.

Absolute power and insertion loss (IL) are accurately measured with this USB power meter when used in conjunction with the corresponding software such as OPL-LOG and OPL-MAX. It is ideal for measuring fibers terminated with simplex connectors such as LC, SC or FC. The OP712 can also be used for high density connectors such as MTP or MPO.

An OP712 outfitted with a large area detector can be used to test high density connectors such as MTP/MPO.

The LAAD series of adapters offer a quick-change magnetic interface and is available for all standard connector options.

Using the OPL-SDK, the user can write custom applications to control the OP712.

Product Features

  • Measurement range
    InGaAs: 1mm, 3mm, 5mm and 10mm
    Silicon: 3mm
    High Power InGaAs: 2mm
  • Remote head is ideal for rugged cables and ergonomic in manufacturing environments
  • Calibration factors stored directly within the OP712
  • System integration with OPL series software suite.
  • Adapters available for universal ferrule sizes (1.25/1.6/2.0/2.5mm) and common connector types
    such as MTP/MPO, MT Ferrule, MT-RJ, LC, FC, SC, PRIZM-LT, MXC etc.
  • Bare fiber adapters available for simplex or ribbon fiber
  • 0.02dB relative accuracy when optical loss is less than 10dB

 

Product Specs


Return LossSingle ModeFTTX Multimode
Source Wavelength1310nm, 1550nm1310nm, 1550nm, 1490nm, 1625nm850nm, 1300nm
Calibrated
Measurement Range
-10dB to -80dB-10dB to -80dB-10dB to -58dB
Measurement Linearity±1dB (-12dB to -72dB)±1dB (-12dB to -72dB)±1dB (-10dB to -45dB)
Distance Rangeup to 2500 meters
Mandrel-free minimum distance1.7 meters (both reflections <-45dB)
Insertion LossSingle ModeFTTX Multimode
Source Center Wavelength±30nm from nominal±30nm from nominal±30nm from nominal
Source Bandwidth<10nm<10nm<140nm (850nm) <200nm (1300nm)
Internal Fiber9/125μm (SMF28)9/125μm (SMF28)50/125μm, 62.5/125μm, 105/125μm
Launch ConditionN/AN/AAvailable upon request
Output Power* (typical)-1.5dBm-2.5dBm-18dBm(850nm) -20dBm(1300nm):
62.5/125μm
Insertion Loss Stability**±0.02dB±0.02dB±0.02dB
Measurement Linearity (Relative Accuracy)***
Deviation ± 0.05dB0dBm to -65dBm at 1490nm
Deviation ± 0.01dB<10dB power variation

*For single channel systems. **Over 1 hour with a max. change of 1ºC. ***For 1, 2, and 3mm detectors.

Optical Power Meter1mm InGaAs3mm InGaAS5mm InGaAs10mm InGaAs3mm Silicon
Measurement Range+6dBm to -72dBm
at 1490nm
+3dBm to -72dBm
at 1490nm
0dBm to -65dBm
at 1490nm
0dBm to -55dBm
at 1490nm
0dBm to -65dBm
at 980nm
Wavelength Range850nm to 1650nm400nm to 1100nm
Selectable Wavelength Standard wavelengths (850nm, 980nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm)Standard wavelengths
(650nm, 850nm, 980nm)
Measurement Resolution (Display)0.001dB
Absolute Accuracy±0.25 dB at calibration conditions for all NIST traceable wavelengths
Measurement Linearity (Relative Accuracy)
Deviation ± 0.05dB+3dBm to -65m
at 1490nm
0dBm to -65dBm
at 1490nm
0dBm to -55dBm
at 1490nm
0dBm to -45dBm
at 1490nm
0dBm to -55dBm
at 980nm
Deviation ± 0.01dB<10dB power
variation
<10dB power
variation
<10dB power
variation
<10dB power
variation
<10dB power
variation
Source1310nm/1550nm LASER1310nm/1490nm/1550nm/1625nm LASER 850nm/1300nm LED
Source Center Wavelength±30nm from nominal±30nm from nominal±30nm from nominal
Source Bandwidth<10nm<10nm<140nm (850nm)
<200nm (1300nm)
Internal Fiber9/125μm (SMF28)9/125μm (SMF28)50/125μm, 62.5/125μm, 105/125μm
Launch ConditionN/AN/AAvailable upon request
Output Power (typical)-1.5dBm-2.5dBm-18dBm(850nm) -20dBm(1300nm):
62.5/125μm
Source Stability*±0.02dB±0.02dB±0.02dB

* Over 1 hour with a max. change of 1ºC.

Measurement TimingSingle ModeFTTX Multimode
IL and RL, Dual Wavelength3s*6s3s*
Switching Time (Multichannel)100ms

* Using the front panel in Dual ILRL mode or running OPL-Pro with real-time update enabled.

MainframeHalf-Rack UnitsFull-Rack UnitsOP710s/OP740sOP940-SWs
Dimensions8 ⅜” x 3.5” x 12”16 ¾” x 3.5” x 12”16 ¾” x 3.5” x 8”16 ¾” x 3.5” x 1
Power Supply90VAC ... 264VAC; 47Hz to 63Hz; 0.7Amps (115VAC) 0.4Amps (230VAC); Fuse: T1A, 250V
Warm-up time5-15 minutes
Operating Temperature5℃ to 40℃
Maximum Relative humidity*80%

* For temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C.

Specifications are subject to change, please confirm specific performance characteristics of the product at the time of ordering. All specifications are valid within temperature range of 18ºC to 24ºC unless otherwise noted. For additional specifications please contact OptoTest.